Refrigerator Troubleshooting – Three phase electrical connections

Smaller compressor motors incorporate overload protectors, either internally or externally mounted, and use various small starting devices. By contrast the three phase motor, being larger, requires more sophisticated methods of automatic starting and overload protection, provided by contactors or starters.

Contactors and starters

A contactor is a power operated switch suitable for frequent making and breaking of an electrical circuit. A starter is a power operated switch with inbuilt overcurrent features, employed for starting a motor and protecting it during running. Both controls enable large currents to be switched by means of a system control (thermostat) with low current rating.

Suppliers of these controls are numerous. Each has its own options with regard to overload protection, single phasing protection and accessibility for component replacement. Wiring diagrams for the controls are normally supplied or are available on demand. These should be referred to before any attempt is made to install, make electrical connections to or diagnose faults on the controls. Because of the different types of control, only typical examples are dealt with here. Figure 104 shows connections for single phase starting, and Figure 105 shows a particular three phase starter.

single-phase-starter

types-of-three-phase-starter

Direct-on-line starter

With the standard squirrel cage induction motor, it is advantageous to have DOL starting. This allows a cheaper motor starter and control gear to be used, and also imposes less strain on motors during starting.

However, electrical supply authorities will normally restrict starting currents. DOL starters should only be specified for motors within the supply authority limits.

Figure 106 shows the electrical connections for three phase DOL starters.

three-phase-DOL-starter

three-phase-DOL-starter-2

Popularity: 60% [?]

Related posts:

  1. Refrigerator Repair – IC-22 relay This is another form of solid state relay for non-capacitor and capacitor start motors. It can be used as a...
  2. Refrigerator Repair – Electrical test procedures Supply and control switch 1. Check the electrical supply at the power point, the fuse and the fuse rating. 2....
  3. Refrigerator Troubleshooting – Drive motor installation details Earthing The motor frame must always be connected to the local earth circuit. It is most important to ensure that...
  4. Domestic Refrigerator Troubleshooting – Electrical faults The diagnosis of electrical faults on components and compressors has already been dealt with in previous articles. The following procedure...
  5. Refrigerator Repair – Motor protection The most common cause of motor failure is overheating. This condition is created when a motor exceeds its normal operating...

Top incoming search terms for this post

dol starter -dol starter diagram -3 phase dol starter wiring diagram -electrical diagrams of a refrigerator -fridge connections -dol starter wiring diagram -dol connection -dol diagram -how instal new sarter device friz whirpool -motor 3 phase -overload IC relay ge refridgerator -diagram starter relay refrigerator -electric domestic appliances diagram -I NEED TROULE SHOOTING HELP WITH MY GEA REFRIGERATOR SHOW ME A VIDEO -diagram of three point starter -refregirator motor electrical connection -3 phase refrigerator -direct on line starter -refrigerator troubleshooting diagram -3PHASE MOTOR STARTER CONNECTION -

Post a Response